DIGITAL ENTRANCE/EXIT AREA MONITOR

For facility entrances, waste management areas, inter-department corridors
- Detects gamma radiation
- 0.1 mR/hr - 1 R/hr Range
- Digital display
- Includes two wall-mount NaI (Tl) scintillation detectors with enclosures and cables
- Separate LOW and HIGH alert/alarm with yellow/ red lights, adjustable audible tones
- Detector failure light and tone to signal detector overload or instrument failure
- Low battery warning
- Threshold adjusts from 2 to 100 mV
- Battery continuously trickle charges when unit is operating and connected to wall current
This Area Monitor serves as a radiation sentry/alert for building entrances, halls, and doorways. Equipped with a pair of NaI (Tl) scintillation detectors that mount on both sides of a doorway or hall, the unit continuously monitors incoming and outgoing materials and people for low-level gamma radiation. Typical applications are the monitoring of areas where waste material leaves departments or buildings, and monitoring
emergency room entrances in the event of radiation-related emergencies. The Area Monitor can be set to give a visual and/or audible alert (yellow light, slow beep) when a selected background level has been exceeded, and give an alarm signal (red light, fast beep) when a selected radiation level is reached. Lights and audibles also indicate detector overload, no count from detectors, or instrument failure. A yellow LED illuminates when the battery has less than 2 hours of power remaining. The monitor is wall-mountable. Two 25-foot detector connection cables are included.
SPECIFICATIONS
- Detectors (2): 3" dia x 1" thick (7.6 x 2.5 cm) shielded NAI (Tl) scintillation detectors in NEMA4x enclosures
- Display: 4-digit LED display with 0.8" (2 cm) character height
- Display Units: Can be made to display in µR/hr, mR/hr, R/hr, µSv/h, mSv/h, Sv/h, µrem/hr, mrem/hr, rem/hr, cpm, cps, and others
- Linearity: Reading within ±10% of true value with detector connected
- Response: Typically 3 seconds from 10% - 90% of final reading
- Status: (green light) instrument functioning properly
- Alarm: Low Alarm - indicated by yellow light and slow beep (1 per second) audible tone (can be set at any point from 0.0 - 9999); High Alarm - indicated by red light and fast beep (4 per second) audible tone (can be set at any point from 0.0 - 9999); NOTE: Audible indicators can be configured as a single beep if desired.
- Det Fail: Detector overload, no count from detector, or instrument failure – indicated by red light and audible tone (greater than 68 dB at 2 feet)
- Low Bat: (yellow) indicates less than 2 hours of battery power remaining
- High Voltage: Adjustable from 200 - 2500 volts
- Threshold: Adjustable from 2 - 100 mV
- Dead Time: Adjustable to compensate for dead time of detector and electronics (can be read on display)
- Overload: Senses detector saturation (indicated by display reading “-OL-”)
- Overrange: Indicates radiation field being measured has exceeded counting range of instrument (indicated by display reading “- - - -”)
Data Output: 9 pin connector providing 5 decade logarithmic output, RS-232 output, signal ground connection, FAIL and ALARM signals (current sink), and direct connection to battery and ground - Calibration Controls: Accessible from front of instrument (protective cover provided)
- Power: 115 VAC; 220 VAC or battery power
- Battery Life: Typically 48 hours in non-alarm condition, 12 hours in alarm condition
- Battery Charger: Battery is continuously trickle charged when instrument is connected to line power and turned on
- Battery Dependence: <3% change in readings to battery endpoint
- Monitor Construction: Wall mount aluminum housing with ivory polyurethane enamel paint
- Dimensions:
Monitor electronics unit: 7.4" h x 9.7" w x 2.5" depth (18.7 x 24.6 x 6.4 cm)
Detectors (each): 13" h x 17" w x 8.5" l (33 x 43 x 22 cm)
Connecting cables (each): 25-foot, type "C" connector - Weight:
Monitor electronics unit: 6.5 lb (2.3 kg)
Detectors (each): 32 lb (14.5 kg)
051-022 Monitor, Area, Entrance/Exit, 115 VAC Includes two NaI (Tl) Scintillation Detectors.
051-024 Monitor, Area, Entrance/Exit, 230 VAC Includes two NaI (Tl) Scintillation Detectors.